SynLock BITS Timing Systems

Huawei carrier-class Building Integrated Timing Supply (BITS) systems meet SynLock V3 and T6020 (V6) requirements. They support synchronous Ethernet (Sync-E), plus traditional (E1, 2 MHz) physical layer synchronization.

Choose from 2 flexible, easily configurable models to better control and manage synchronized networks for cloud services and Big Data backup.

Ensure network performance and resiliency with Huawei’s SynLock BITS.

Get Pricing / Info

Huawei’s SynLock BITS Timing Systems provide high-accuracy time and frequency synchronization for large-scale enterprise networks and service providers

Time and frequency synchronization for mobile networks: Outputs high-precision time synchronization signals PTP/1588v2 and 1PPS + TOD at the nanosecond (ns) level, and transmits time signals to LTE-A, LTE-TDD, TD-SCDMA, and CDMA NodeBs through carrier networks

Frequency synchronization for fixed networks: Provides frequency synchronization signals at a precision of 10-12. These signals include 2,048 kbit/s, 2,048 kHz, 1 MHz, 5 MHz, and 10 MHz, for devices on fixed networks

Support Network Time Protocol (NTP): Time synchronization for billing, Network Management Systems (NMS), and Operations and Maintenance (O&M) systems

Specifications

Specification

SYNLOCK V3

SYNLOCK T6020 (V6)

Dimensions (H x W x D)

575 mm x 436 mm x 275 mm

88.1 mm x 442 mm x 220 mm

Satellite Inputs

2 x GPS/GLONASS/BeiDou

2 x GPS/BeiDou

Frequency Inputs

Maximum 20 ports. Can select 2,048 kbit/s, 2,048 kHz, 1 MHz, 5 MHz, or 10 MHz software for each port

Maximum 2 ports. Can select 2,048 kbit/s or 2,048 kHz software for each port

Frequency Outputs

Maximum 300 ports. Can select 2,048 kbit/s, 2,048 kHz, 1 MHz, 5 MHz, 10 MHz, or composite clock 64 kbit/s software for each port; 80 GE/FE ports SYNC-E

Maximum 8 ports. Can select 2,048 kbit/s, 2,048 kHz, 1 MHz, 5 MHz, 10 MHz, composite clock 64 kbit/s software selectable for each ports; 6 FE/2 GE ports SYNC-E, supporting 1588ACR

Time Inputs

2 x 1588 v2, 4 x 1PPS + TOD, and NTP

2 x 1588 v2, 2 x 1PPS + TOD

Time Outputs

Maximum 80 x 1PPS + TOD, 40 x NTP ports; 80 GE/FE 1588 v2 ports

Maximum 8 x 1PPS + TOD, 6 FE/2 GE 1588 v2 ports

Oscillator

Rubidium clock or OCXO clock configuration optional, redundancy backup design

Maintenance

CLI, iManager U2000, and SYNLOCK BITS management suite